RF Isolators and Circulators

Technical Info

Technical information on RF isolators and circulators, including device configurations, application considerations, and drop-in fixture testing and calibration.

Drop-in test fixtures

Three photos showing the drop-in test fixture configurations listed below.
  1. Fixture configured as a through line for the first transmission line measurement.
  2. Fixture with the second through line installed for the second measurement.
  3. Fixture ready to test drop-in units.

Sonoma Scientific designs and tests all drop-in units using 50-ohm microstrip fixtures. Fixture dimensions depend on the operating frequency and the device's tab configuration.

Measurement challenges

At microwave frequencies, it can be difficult to separate the device's response from the effects of the fixture and test system, including leakage, test-port mismatch, and frequency response. Microstrip impedance standards can also be difficult to characterize: shorts are inductive, opens radiate energy, and purely resistive loads are hard to build.

Two common sources of measurement error are:

  1. Impedance discontinuities at the transition from coax to microstrip. Reflections at this transition can be larger than those at the device interface.
  2. Signal loss in both the coaxial and microstrip portions of the fixture.

Line-reflect-line calibration

To compensate for fixture effects, Sonoma Scientific uses line-reflect-line (LRL) calibration rather than a standard 12-term calibration. LRL uses transmission lines as calibration standards. A full calibration includes measurements of two transmission lines, a highly reflective standard, and isolation.

A separation of at least two wavelengths between the coax-to-microstrip transitions is recommended to reduce the effect of higher-order mode coupling on the calibration.

The test equipment compensates for microstrip dispersion using these parameters:

  • Reference characteristic impedance
  • Effective dielectric constant
  • Substrate dielectric constant
  • Substrate thickness
  • Trace width

Circulator overview

An RF circulator is a passive, nonreciprocal three-port device that uses ferrite to direct RF energy from each port to the next in a fixed direction. An isolator is a circulator with one port terminated in a load to absorb reflected power.

In an isolator configuration, a circulator offers two main benefits:

  1. Helps maintain a good input match, even when the load at the output is poorly matched.
  2. Provides a low-loss path for the forward signal while protecting the source by routing reflected power to a termination.

Circulators are used in RF matching networks, to protect equipment when an antenna becomes open, shorted, or overloaded, and as duplexers that let a transmitter and receiver share an antenna.

Design considerations include frequency, bandwidth, isolation, insertion loss, voltage standing wave ratio (VSWR), power, altitude, intermodulation distortion (IMD), operating temperature, size, orientation, phase, and group delay. Common configurations include waveguide, drop-in, coaxial, microstrip, surface-mount, and hybrid designs. A hybrid can use a connector on one port and a tab on an adjacent port.

Applications include cellular and WiMAX infrastructure, phased-array radar, public safety radio, aircraft Doppler systems, missile guidance, point-to-point radio, medical equipment, food processing, satellite systems, signal jamming, and test equipment.